Trane serial number nomenclature. May 1, 2023 · The date of the production or manufac...

Dec 2, 2016 · Post Likes. Originally Posted by rundawg. Your Y

optional Trane thermostat control, and air distribution ducts, you have a highly efficient, total home comfort system. Single Packaged Electric Heat Pump Systems are unmatched in quality and reliability. All major components on these products, including the compressor, have been designed and manufactured for maximum service.Browse these resources from Trane to find information on your unit or system, maintenance tips, common HVAC terms and more.Trane serial number nomenclature includes: Manufacturing date (year, month, week, day) Manufacturing location Sequential number Serial number Examples: Serial Number #1E-123456 (used in 1970's) 1 = 1971 E = May Serial Number #P16-12ABCD (used in 1983) P = 1999 16 = week Serial Number #03161-ABCDE (used in 2002-2009) 03 = 2003 16 = week 1 = dayHow does one tell tonage and etc inside this trane voyager model number. I tried to search old threads but came up empty. Any help appreciated.:) M# - YCD600AEHC2B8NE400C00FOHJ000 S# - CO3M10968Trane serial number nomenclature includes: Manufacturing date (year, month, week, day) Manufacturing location Sequential number Serial number Examples: Serial Number #1E-123456 (used in 1970's) 1 = 1971 E = May Serial Number #P16-12ABCD (used in 1983) P = 1999 16 = week Serial Number #03161-ABCDE (used in 2002-2009) 03 = 2003 16 = week 1 = dayJan 4, 2019 · Trane Nomenclature/Model # breakdown. Trane. YSC090E4ELA0E000000000000C. Serial# 114011252L. I am having hard time finding resources to break down this model/serial to find the age of unit. I notice several guides for other models but not this one, unless I overlooked it. Reply. Calculators Trane HVAC Age: Serial Number Decoding for AC, Furnace & Heat Pump July 22, 2022 | By Rene Langer Trane age of unit - here is how to read a Trane serial number: For units made from 2002 to 2009, the first number represents the year: 2 is 2002, 3 is 2003, etc.Search for the data tag or sticker plate on the unit. You will find all the detailed information for your unit in the data tag. Thanks to the data tag, the serial number, model number, ANSI rating, etc., will be found out. Here’s where you will find the manufacture date, depending on the Trane product you purchased:See “Unit Model Number Description,” p. 8 and “Compressor Model Number Description,” p. 9 for details. Each position, or group of positions, in a number or letter is used to represent a feature. For example, from the chart, we can determine that the letter “F” in digit 8 of the unit model number indicates unit voltage is 460/60/3. 2 22-1928-1b-en product specifications model no. (a) (b) 4tta4036a3000a 4tta4042a3000a 4tta4048a3000a 4tta4060a3000a power conns. — v/ph/hz (c) 208/230/3/60 208/230/3/60 208/230/3/60 208/230/3/60 min. brch. cir. ampacity 12 15 18 21 br. cir. prot. rtg. — max. (amps) 20 25 30 35 compressor climatauff®- scroll climatuff®- scroll climatuff®- scroll …The first letter of the Trane serial number nomenclature gives the year of manufacture and the next two numbers are the week . In 2002 they started their serial numbers with the year it was built. In 2002 the first character of the serial number is 2, in 2003, 3 and so on.Privacy Policy. For Product Registration Assistance Please Call {{phoneNumber}} or Email: [email protected] {{phoneNumber}} or Email: product ...Packaged Rooftop Air Conditioners Precedent™ — Gas/Electric 3 to 10 Tons — 60 Hz Installation, Operation, and Maintenance January 2021 RT-SVX21AC-EN Model Numbers: YSC036G - YSC060G YHC072F - YHC102FAir Conditioner Trane Voyager CV Installation And Maintenance Manual. 27.5 to 50 ton 60 hz 22.9 to 41.7 ton 50 hz cv, vav, or sz vav rooftop air conditioners with reliatel controls, r-410a refrigerant (122 pages) Air Conditioner Trane Voyager TC* User Manual. Packaged cooling & gas/electric rooftops 12 1/2-25 tons — 60 hz (109 pages) Air ...Description: Ten (10) character Serial number. Begins with one (1) letter digit followed by one (1) numerical digit, then another one (1) letter digit and ends with seven (7) numerical digits. Year of manufacture is 2nd-4th numerical digits combined. Month of manufacture is 3nd character, which is a letter digit. (See chart below).lost. Trane’s helical rotary compressors have been designed and built to stay running when you need them. Fewer moving parts. Trane’s helical rotary compressors have only two major rotating parts: the male and female rotor. A reciprocating compressor can have more than 15 times that number of critical parts. Multiplesnumber. Thefourconfigurationsare: 1. Frontreturn-airwithbacksupply-air combination 2. Frontreturn-airwithtopsupply-air combination 3. Backreturn-airwithfrontsupply-air combination 4. Backreturn-airwithtopsupply-air combination q A O 3 *”Z00” 0;0” 0;0” 0 SUPPLY *”Z0;0” *”Z0;0” 0 SUPPLY 00” AccessPanels TheupperpanelsoftheGEV12 ...Aug 10, 2023 · Trane serial number nomenclature includes: Manufacturing date (year, month, week, day) Manufacturing location Sequential number Serial number Examples: Serial Number #1E-123456 (used in 1970’s) 1 = 1971 E = May Serial Number #P16-12ABCD (used in 1983) P = 1999 16 = week Serial Number #03161-ABCDE (used in 2002-2009) 03 = 2003 16 = week 1 = day Example serial number styles/formats found: The Serial Numbers shown are utilized with all Paloma Brand systems. Style 1: 1204D01234. Style 2: OR177 M2807 00097. Style 3: W291013412. Style 4: CB5D302F099903346. Style 5: 123451872.As we’ve mentioned, manufacturers change the parts they’ve used on the assembly line for various reasons. Here’s how to read the model number on your American Standard furnace: T- is the brand identifier and can be A (American Standard) or T (Trane) U- is the furnace configuration and can be: U- Upflow /Horizontal. D- Downflow/Horizontal. 8 Jun 2023 ... FAQ for Samsung Air Conditioner. Find more about 'Serial Number on the Air-conditioner' with Samsung Support.Air Conditioner trane IntelliPak Programming Manual. With symbio 800, 20 to 75 ton with the tracer td7 display (88 pages) Air Conditioner Trane Voyager III Installation Manual. Variable frequency drive conversion tr1 to tr200 (24 pages) Air Conditioner Trane IntelliPak Signature Series Programming Manual.The date of production/manufacture or age of Mitsubishi® HVAC equipment can be determined from the serial number located on the data plate. Various serial number styles/formats have been encountered. The two styles we have listed will code the year of manufacture in the first digit. The decade must be assumed based on nearest ANSI code date or ...6 BAYCURB051A Full Perimeter Roof Mounting Curb for *****042-060A 56 1/8 15 7/8 3 10 7/8 19 1/2 4 3/4 19 1/2 14 41 7/8 20 1 1/2 38 7/8 53 1/8 The drawings on this page are pre-Here’s a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. And this is another one that is 2.5 tons. Also, Trane is the only brand we are familiar with that occasionally lists a two-digit number for the thousands of BTU rating that is not divisible by ...VariTrane® Single Duct Terminal Units. VariTrane ® variable-air-volume (VAV) units lead the industry in quality and reliability and are designed to meet the specific needs of today’s applications. Help to control comfort, indoor air quality (IAQ), noise levels, and energy consumption with the VariTrane single duct terminal units.The CGAM air-cooled scroll chiller offers the perfect combination of flexibility, efficiency and low noise. Available in sizes ranging from 20 to 130 tons with a compact footprint, the CGAM is one of the quieter air-cooled …age of American Standard/Trane furnace. Specific Inspection Topics Inspecting HVAC Systems. jmulhern (John Mulhern) March 7, 2018, 4:08pm 1. this appears to be a newer unit 1 to 2 years but I cant figure it out by the serial number , any help would be appreciated. 2000×1125 263 KB.If you do not see the correct model you're looking for then you may want to try and search for the Trane product using the search bar above. 012 GEH - Dehumidifier; 049E - Air Conditioner; 080 - Furnace; 100 - Furnace; 120 GEH - Dehumidifier; 120R9V - Furnace; 18-AB33D1-5 - Package Unit;refer to the Trane Residential and Light Commercial Product Handbook. Sound Power Level MODEL A-Weighted Sound Power Level [dB(A)] Full Octave Sound Power(dB) 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TTR3018H1 72 73.7 71.4 65.4 68 67.3 62.9 56 50.3 4TTR3024H1 74 47.9 60.5 64.1 71.2 71.2 69.0 58.2 51.5age of American Standard/Trane furnace. Specific Inspection Topics Inspecting HVAC Systems. jmulhern (John Mulhern) March 7, 2018, 4:08pm 1. this appears to be a newer unit 1 to 2 years but I cant figure it out by the serial number , any help would be appreciated. 2000×1125 263 KB.Mitsubishi: The first number in the serial number indicates the year of manufacturing. You must assume the decade. (For example, an “8” could mean the equipment was manufactured in 2008 or 2018.) Bottom Line Always take a moment to familiarize yourself with the manufacturer's model/serial number nomenclature.* The information above is intended to be used as a guide to confirm the warranty coverage for the serial number you enter. Every attempt has been made to confirm its accuracy. At times, the information may not be readily available.Trane TTA120A series Installation Operation & Maintenance (32 pages) Split System Cooling Condensers 7 1/2 - 20 Tons. Brand: Trane | Category: Air Conditioner | Size: 2.63 MB. Table of Contents. Table of Contents. 3.Thermafit™ Water-Cooled Modular Chillers. [Models MWC, MWT] At a glance. 15-80 tons (800 ton bank) Model MWC standard efficiency. 20-40 tons (400 ton bank) Model MWT high efficiency. Provides cooling. Heat recovery option available. Available with R-410A with option for R-134a. Meets ASHRAE 90.1 for cooling.VariTrane® Single Duct Terminal Units. VariTrane ® variable-air-volume (VAV) units lead the industry in quality and reliability and are designed to meet the specific needs of today’s applications. Help to control comfort, indoor air quality (IAQ), noise levels, and energy consumption with the VariTrane single duct terminal units.number. Thefourconfigurationsare: 1. Frontreturn-airwithbacksupply-air combination 2. Frontreturn-airwithtopsupply-air combination 3. Backreturn-airwithfrontsupply-air combination 4. Backreturn-airwithtopsupply-air combination q A O 3 *”Z00” 0;0” 0;0” 0 SUPPLY *”Z0;0” *”Z0;0” 0 SUPPLY 00” AccessPanels TheupperpanelsoftheGEV12 ... middle of the serial number. Example: xxxx1872 = 18th week of 1972 _____ Tappan Capacity: Look for those elusive two digits in the model number (usually, but not always) divisible by 6 and divide by 12 to convert to tons. Example: CM36-11B,T = 3 ton _____ Trane Capacity: Trane has used a number of different methods for encoding capacityTrane Acoustics Program (TAP) makes these algorithms easier to use. Step 4: Sum the results to determine the acoustical performance of the installation. Once the contributions of the individual paths for a particular receiver location are calculated, they must be added together to determ ine the total sound at the receiver.Trane chiller serial number nomenclature Howdy folks, I can't believe that I'm not finding this in the forums, but does anybody have Trane's serial number nomenclature on hand? I'm trying to figure out how old this RTAA-125 chiller is. I found nomenclature on Trane's residential units, but it doesn't appear to apply to the …May 1, 2023 · The date of the production or manufacture is hiding in the 2nd and 3rd digits serial number. The second letter is the month of manufacture and the third letter is the year of manufacture. From here we can determine the York HVAC age from serial number. Old Serial Number format will look like this: YBVM220710, BDHM203490, BKVM310394 etc.. Trane chiller serial number nomenclature Howdy folks, I can't believe that I'm not finding this in the forums, but does anybody have Trane's serial number nomenclature on hand? I'm trying to figure out how old this RTAA-125 chiller is. I found nomenclature on Trane's residential units, but it doesn't appear to apply to the …lost. Trane’s helical rotary compressors have been designed and built to stay running when you need them. Fewer moving parts. Trane’s helical rotary compressors have only two major rotating parts: the male and female rotor. A reciprocating compressor can have more than 15 times that number of critical parts. Multiples How to determine the date of production/manufacture or age of York ® brand HVAC Systems. The industry average service design life for most forced air furnaces is 15-20 years, and the industry average service design life for most air conditioning condensing units is 10-15 years. The average service design life of boilers can vary from as little ...Visit Trane Supply. UniTrane units are individual room air conditioners used in office building, apartments, dormitories, schools, motels and hotels. UniTrane fan-coils units are available with optional hot water, steam and electric heating coils for added flexibility. Units are attractively styled and have durable, heavy gauge steel construction.Make sure you’ve entered your serial number correctly. If you’re trying to register a new ductless system, enter the serial number followed by a “-” and then the model number (example: 5001234T-MSZ-GE25VA-E1). 7.2-3 Table 7.2.7 Trane/American Standard Model Number Description T U Y 080 R 9 V3 V 0 Brand Identifier Furnace Configuration Type Heating Input (mbtu/h)The third and fourth digits of the serial number are the year of manufacture of a Gree heat pump. This condenser was manufactured in 2018. Gree also lists the date of manufacture in a year/month format on the data plate. To find out the age of another brand of air conditioner or heat pump, go to How do I determine the age of my air conditioner ...Air Conditioner Trane Precedent YSC060-120 User Manual. Packaged gas/electric rooftop units 50hz (61 pages) Air Conditioner Trane YSC060ED Installation, Operation And Maintenance Manual. Packaged rooftop air conditioners precedent — gas/electric 5 – 10tons – 50 hz (48 pages)The CGAM air-cooled scroll chiller offers the perfect combination of flexibility, efficiency and low noise. Available in sizes ranging from 20 to 130 tons with a compact footprint, the CGAM is one of the quieter air-cooled …The first letter of the Trane serial number nomenclature gives the year of manufacture and the next two numbers are the week . In 2002 they started their serial numbers with the year it was built. In 2002 the first character of the serial number is 2, in 2003, 3 and so on. How many tons is a Trane XL 1200? Trane XL1200 air conditioner is ...table, position 08 of the unit model number, Unit Voltage, contains the number “4”. A 4 in this position means that the unit voltage is 460/60/3. Unit Model Number. An example of a typical unit model number (M/N) is: Model number digits are selected and assigned in accordance with the definitions as listed in “Unit Model Number,” p. 7.Accessory Number Description Fits Cabinet Size BAYHTR1504BRK Electric Heater, 4KW, Breaker, 24V Control, 1 Ph 18.5” and 23.5” BAYHTR1504PDC Electric Heater, 4KW, Pull Disconnect, 24V Control, 1 Ph 18.5” and 23.5” BAYHTR1504LUG Electric Heater, 4KW, Lug, 24V Control, 1 Ph 18.5” and 23.5”The date of production/manufacture or age of DAIKIN® HVAC equipment can be determined from the serial number or MFG. DATE located on the data plate. Parent Company: DAIKIN North America LLC (Subsidiary of Daikin Global aka Daikin Industries, Ltd.) Style 1: Serial No. A000129 with MFG. DATE 2008-1.The CGAM air-cooled scroll chiller offers the perfect combination of flexibility, efficiency and low noise. Available in sizes ranging from 20 to 130 tons with a compact footprint, the CGAM is one of the quieter air-cooled …Application Capacity. Application Capacity is capacity associated with a nominal 10°F TD, 25°F/-20°F SST application condition historically established to successfully size equipment and components to satisfy a heat load, net of all influences, in an application. Enter your legacy model number. Lookup New Equivalent Model.Nomenclature T U D 1 B 0 8 0 A 9 H 3 1 A A Furnace Configuration TU = Upflow/Horizontal TD = Downflow/Horizontal Type E = 80% Induced Draft Standard D = 80% Induced Draft Premium C = 90% Condensing Standard X = 90% Condensing Premium H = 95% Condensing Premium Number of Heating Stages 1 = Single Stage 2 = Two Stage M = Modulating Major Design ...Phone Number. Next. Step 1 of 2. Street Address. City. ... The Trane Comfort Coil unit is the industry’s first All-Aluminum coil. With over 10 years of performance, the Trane Comfort Coil has the reliability and efficiency you expect from Trane and the comfort your home deserves. Below are a few of the features and benefits that are included ...Please advice how to interpret month of manufacturing date from Trane chiller serial number. The 4th alphanumeric will be a letter. It's order in the alphabet is the month of manufacture. The letter "I" is skipped, not used, due to the possibility of it being mistaken for the numeral "1". For example, in the made up serial number "L09H1234 ...Trane offers a complete family of packaged gas/electric heating and cooling systems, designed to provide the unbeatable combination of energy efficiency and lower operating costs. In warm weather, the package gas/electric system functions as an all-electric, high efficiency air conditioner.Typically used to identify tangible and intangible consumer goods, serial numbers are made up of a series of numbers (and sometimes letters and characters) that are unique to that individual product, piece of software or other item. Learn a...Application Capacity. Application Capacity is capacity associated with a nominal 10°F TD, 25°F/-20°F SST application condition historically established to successfully size equipment and components to satisfy a heat load, net of all influences, in an application. Enter your legacy model number. Lookup New Equivalent Model.5 Unit Performance Data 2YCC Performance Data Cooling 2YCC3036A AT 1200 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 75 78 80 KWThe model number decoder and serial number decoder for all major brands. Get this application to save time and money for only $9.99. Choose your platform to run the app. Trane Model Number Decoder. ... The Trane model number nomenclature is broken down into segments. Each segment will have a number of letters and/or digits.Jul 22, 2022 · The new style of York serial number nomenclature is now identical to Luxaire and Coleman serial numbers and decoding method for age of units. Style #2: 10 Characters – 4 Letters + 6 Numbers – 1971 to 2001. This section covers York serial number decoding for manufacture dates from 1971 to September 2004. position, and the service model number. Note: This information is required when ordering parts or requesting service for a T-Series air handler. Figure 1. T-Series air handler section nameplate Module type Module location in direction of airflow Module serial number Unit tagging Module service model number Additional module specific information ...Example serial number styles/formats found: The Serial Numbers shown are utilized with all Paloma Brand systems. Style 1: 1204D01234. Style 2: OR177 M2807 00097. Style 3: W291013412. Style 4: CB5D302F099903346. Style 5: 123451872.Description: Ten (10) character Serial number. Begins with one (1) letter digit followed by one (1) numerical digit, then another one (1) letter digit and ends with seven (7) numerical digits. Year of manufacture is 2nd-4th numerical digits combined. Month of manufacture is 3nd character, which is a letter digit. (See chart below).Jul 22, 2022 · Trane age of unit – here is how to read a Trane serial number: For units made from 2002 to 2009, the first number represents the year: 2 is 2002, 3 is 2003, etc. The next two numbers are the week of the year, so 01 would be the first week in January, and 52 would be the last week in December. Our packaged units and split systems are available in a broad range of capacities. All with Trane quality, efficiency and reliability. Built to Last. Trane quality and reliability is the result of extensive design validation and product testing to get it right – whether installed right out-of-the-box or with factory installed options or ...Air Conditioner Trane Precedent YSC060-120 User Manual. Packaged gas/electric rooftop units 50hz (61 pages) Air Conditioner Trane YSC060ED Installation, Operation And Maintenance Manual. Packaged rooftop air conditioners precedent — gas/electric 5 – 10tons – 50 hz (48 pages)age of American Standard/Trane furnace. Specific Inspection Topics Inspecting HVAC Systems. jmulhern (John Mulhern) March 7, 2018, 4:08pm 1. this appears to be a newer unit 1 to 2 years but I cant figure it out by the serial number , any help would be appreciated. 2000×1125 263 KB.The serial number indicates age from 1972 and later. ----- Coleman Prior to April 1992, the serial number’s first two numbers are the month, then year, then series. After April 1992, the first two numbers are the year, then month, then series. ----- Comfortmaker (International Comfort) The serial number is a letter followed by a nine-digit ...information, the module serial number, and the service model number. Refer to the module nameplate to ensure proper placement of the modules during assembly. Figure 1. M-Series module nameplate/label Type of module Service model number Module position Tagging info. Serial number Supply Fan Drive Location K01Z12345 If the unit ships as individual Thermafit™ Water-Cooled Modular Chillers. [Models MWC, MWT] At a glance. 15-80 tons (800 ton bank) Model MWC standard efficiency. 20-40 tons (400 ton bank) Model MWT high efficiency. Provides cooling. Heat recovery option available. Available with R-410A with option for R-134a. Meets ASHRAE 90.1 for cooling.HVAC BRAND MODEL NUMBER NOMENCLATURE. Select one of the drop-down lists below. that corresponds to the FIRST letter. of your HVAC brand name. Then make your selection from the list.As we’ve mentioned, manufacturers change the parts they’ve used on the assembly line for various reasons. Here’s how to read the model number on your American Standard furnace: T- is the brand identifier and can be A (American Standard) or T (Trane) U- is the furnace configuration and can be: U- Upflow /Horizontal. D- Downflow/Horizontal.Trane Products Reference Page. Trane XL20i: MODEL. 4TTZ0024A1 4TTZ0036A1 4TTZ0048A1 4TTZ0060A1. TONS. 2 Tons 3 Tons 4 Tons 5 Tons. Cooling Capacity (BTUH).Our packaged units and split systems are available in a broad range of capacities. All with Trane quality, efficiency and reliability. Built to Last. Trane quality and reliability is the result of extensive design validation and product testing to get it right – whether installed right out-of-the-box or with factory installed options or ... How to read the Trane Serial Number. Let’s take a closer look at how to decode every digit of a Trane serial number. Trane serial number nomenclature consists of: Manufacturing date: year, month, week, and day; Manufacturing location; A sequential number; Here are some serial number examples: Jun 23, 2018 · How can I tell the age of a Trane furnace from the serial number? 1) 2002 to present - If the serial number is a 9-digit combination of letters and numbers that starts with a number, then the first number is the year. Beginning in 2010, the first two digits are the year. The serial number below indicates the furnace was manufactured in 2002. 4TTZ0048A1000AA is a Trane 48,000 BTU or 4 ton system If you are unable to read the label you can look down into the condensing unit from the top to see the compressor and often use the compressor part number to determine the tonnage using Google. Age: The age is generally encoded into the serial number. You can find your serial number on the product itself or listed on your invoice. You can also contact our Warranty Specialists at 1-855-260-2975 or email …©2021 Trane UNT-PRC001R-EN Introduction. UniTrane™ fan coils are intended for single zone applications. These units have load capabilities of 200 to 1200 . cfm. Fan coils provide cooling and heating, and are available as two-pipe, with or without electric heat (one hydron ic circuit) or four-pipe (two hydron ic circuits). These units feature. Here’s a rundown of the range you will encounter: 18 = 1.Trane M-Series Climate Changer air handlers are central- Example 2: Trane XR16 Model Number 4TTR6030J1000A. Using Method 1, we can see that the first digit of this model number is a 4, which corresponds to 3 tons of cooling capacity. Therefore, the tonnage of the Trane XR16 model number 4TTR6030J1000A is 3 tons. Example 3: Trane XV20i Model Number 4TWZ0048B1000A. Our packaged units and split systems are ava Model Numbers: GEHE 006-060 - 50/60 Hz GEVG 006-060 - 60 Hz GEHE 072-180 - 50/60 Hz GEVE 072-300 - 50/60 Hz ©2021 Trane WSHP-SVX01AA-EN Introduction Read this manual thoroughly before operating or servicing this unit. Warnings, Cautions, and Notices Safety advisories appear throughout this manual asHow to determine the date of production/manufacture or age of Lennox ® brand HVAC Systems. The industry average service design life for most forced air furnaces is 15-20 years, and the industry average service design life for most air conditioning condensing units is 10-15 years. The average service design life of boilers can vary from as ... Description: Ten (10) character Serial number. Begins with one (1) let...

Continue Reading